Work from what you can see with the machine on, then move to measurements with it off. Most no-steam calls are a level fault, a tripped safety thermostat, or a heating element that has failed open.

With the machine on

  1. Read the boiler gauge. Once fully warm, the steam boiler should sit at the setpoint in the manual (typically around 1 to 1.4 bar). Zero or barely moving means the boiler isn't heating.
  2. Look for a level error. If the boiler can't refill in time the machine shows a level error (flashing lights) and stops heating. Switch it off for a few seconds and back on, then watch whether it fills.
  3. Watch the fill. A machine that keeps trying to fill but never gets there points to the water supply, the fill solenoid or the level probe.

Machine off, unplugged, pressure released, cooled

  1. Safety thermostat. The manual-reset safety thermostat (often called the klixon) trips if the boiler overheats. Press its reset button. If it trips again, find out why — usually a low water level or a stuck heating control.
  2. Heating element. Measure across the element terminals. A healthy element reads a few to a few dozen ohms per coil (expected ohms = volts² ÷ watts of that coil). An open circuit (OL) means the element has failed. Also check each terminal to ground.
  3. Pressure switch. If the element is good and the boiler still won't reach pressure, check the pressure switch contacts and its setting.